X12 EDI Connector 2.19 Control Numbers

Use the Write operation in Anypoint Connector for X12 EDI (X12 EDI Connector) to generate control numbers in the X12 payload:

  • Managing global control numbers through control number keys

  • Managing identifier combination control numbers

  • Using your own control number

Manage Global Control Numbers Through Control Number Keys

If your organization or trading partner must maintain unique interchange, group, or transaction set control numbers across different identifier combinations and document types:

  • Set the configuration Use supplied values to false.

  • Leverage the control number key configurations (at the configuration level or operation level) to set a key unique to the partner.

    By default, the control number key configurations are passed dynamically at the operation level. Use this group control number key across different identifiers and transaction types for the same partner.

X12 EDI Connector Control Numbers

Manage Identifier Combination Control Numbers

If you want the connector to automatically maintain control number sequencing based on the sender/receiver identifiers and you do not require global control numbers at a partner level, then set the Write configuration Use supplied values to false. When no value passes into the optional interchange, group, or transaction number key configurations, the sender/receiver identifier combination is the default.

Use Your Own Control Number

If you must generate control numbers and use them in the EDI payload, set Use supplied values to true and map the control number in the DataWeave script.